The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this information for consumers
Trial registered on ANZCTR


Registration number
Help: Registration number
ACTRN12626001169336
Ethics application status
Help: Ethics application status
Approved
Date submitted
Help: Date submitted
1/09/2026
Date registered
Help: Date registered
21/09/2026
Date last updated
Help: Date last updated
21/09/2026
Date data sharing statement initially provided
Help: Data sharing statement date
21/09/2026
Type of registration
Help: Type of registration
Retrospectively registered

Titles & IDs
Public title
Using bedside ultrasound to confirm central venous catheter placement in adult intensive care patients
Scientific title
A randomised controlled trial of point-of-care ultrasound versus standard chest X-ray confirmation of central venous catheter placement in adult intensive care patients: diagnostic accuracy of catheter position confirmation
Additional trial identifiers [1] 318163 0
Nil known
Universal Trial Number (UTN)
Trial acronym
ULTRA-CVC (Ultrasound-Led Timely Recognition and Assessment of Central Venous Catheter Placement)
Related trial records

Health condition
Health condition(s) studied:
Requirement for central venous catheter insertion in intensive care patients 343463 0
Procedural complications of central venous catheter insertion (e.g. pneumothorax, malposition) 343587 0
Condition category
Condition code
Anaesthesiology 339562 339562 0 0
Other anaesthesiology
Public Health 339691 339691 0 0
Health service research
Cardiovascular 339692 339692 0 0
Diseases of the vasculature and circulation including the lymphatic system

Intervention/exposure
Study type
Interventional
Description of the intervention or exposure
Intervention arm: Point-of-care ultrasound (POCUS) plus chest X-ray (CXR).
Following clinically indicated insertion of an internal jugular or subclavian central venous catheter (CVC), bedside POCUS will be performed by an ICU doctor. Ultrasound assessment will include confirmation of the catheter within the cannulated vein, followed by a rapid saline flush through the CVC while imaging the right atrium using a subcostal cardiac ultrasound view. Correct catheter placement will be supported by visualisation of the rapid atrial swirl sign following the saline flush.
If the rapid atrial swirl sign cannot be confidently visualised with a standard saline flush, agitated saline contrast may be used as a secondary confirmation technique.
Bilateral lung ultrasound will also be performed to assess for pneumothorax. A chest X-ray will subsequently be performed in all participants as the current standard method of CVC confirmation. The times of ultrasound and chest X-ray confirmation will be recorded.

Intervention
The bedside POCUS assessment is expected to take approximately 5 minutes, inclusive of vascular confirmation, saline flush/rapid atrial swirl sign assessment, and bilateral lung ultrasound for pneumothorax. The chest X-ray is expected to take approximately 30–45 minutes from request to image availability, in accordance with usual hospital radiology workflow, and will be performed by hospital radiography staff. The POCUS confirmation protocol will be performed once per participant, immediately following clinically indicated CVC insertion; if the catheter is subsequently dislodged or reinserted during the same ICU admission, the protocol may be repeated for the new catheter. Adherence to the POCUS protocol will be monitored via the study data collection form, which records completion of each protocol step, together with proceduralist-reported deviations.

Comparator
The chest X-ray is expected to take approximately 30–45 minutes from request to image availability and will be performed by hospital radiography staff, in accordance with standard hospital practice.
Intervention code [1] 335225 0
Diagnosis / Prognosis
Description of the comparator or control
Control arm: Standard chest X-ray confirmation.
Following clinically indicated insertion of an internal jugular or subclavian CVC, a chest X-ray will be requested after CVC insertion in accordance with current standard practice. Catheter position and procedure-related complications will be assessed using the chest X-ray, and the time of CVC confirmation using chest X-ray will be recorded. The chest X-ray is expected to take approximately 30–45 minutes from request to image availability and will be performed by hospital radiography staff, in accordance with standard hospital practice.
Control group
Active

Outcomes
Primary outcome [1] 346738 0
Diagnostic accuracy of point-of-care ultrasound for confirmation of correct central venous catheter placement
Timepoint [1] 346738 0
Immediately following central venous catheter insertion, with point-of-care ultrasound performed at the bedside and compared with the post-insertion chest X-ray obtained during the same episode of care.
Secondary outcome [1] 467271 0
Time from central venous catheter insertion to confirmation of correct catheter placement
Timepoint [1] 467271 0
From completion of central venous catheter insertion until confirmation by point-of-care ultrasound and chest X-ray during the same episode of care.
Secondary outcome [2] 467272 0
Inter-operator reliability of point-of-care ultrasound assessment for central venous catheter confirmation
Timepoint [2] 467272 0
During the point-of-care ultrasound assessment immediately following central venous catheter insertion.
Secondary outcome [3] 467273 0
Diagnostic accuracy of point-of-care ultrasound for detection of post-procedural pneumothorax
Timepoint [3] 467273 0
Immediately following central venous catheter insertion during the post-procedural point-of-care ultrasound and chest X-ray assessments.
Secondary outcome [4] 467274 0
Cost of central venous catheter confirmation strategy
Timepoint [4] 467274 0
During the index central venous catheter insertion and confirmation episode.
Secondary outcome [5] 467276 0
Time from central venous catheter insertion to first clinical use
Timepoint [5] 467276 0
From completion of central venous catheter insertion until first clinical use during the same episode of care.
Secondary outcome [6] 467277 0
Adherence to the point-of-care ultrasound central venous catheter confirmation protocol
Timepoint [6] 467277 0
At completion of the central venous catheter confirmation procedure for each enrolled participant.

Eligibility
Key inclusion criteria
Adults aged over 18 years admitted to the Intensive Care Unit who require insertion of a central venous catheter in the internal jugular or subclavian vein within the Intensive Care Unit. Eligible catheter types include multilumen central venous catheters and vascular dialysis catheters (VasCath).
Minimum age
18 Years
Maximum age
No limit
Sex
Both males and females
Healthy volunteers
No
Key exclusion criteria
1. Femoral central venous catheter insertion or long-term tunnelled internal jugular/subclavian vascular dialysis catheter.

2. Central venous catheter inserted outside the Intensive Care Unit, including in the Emergency Department or operating theatre.

3. Chest trauma.

4. Known pneumothorax.

5. Current post-cardiothoracic surgery with sternotomy incision.

6. Poor cardiac point-of-care ultrasound windows, including those associated with obesity, anatomical chest deformity or emphysematous lung disease.

Study design
Purpose of the study
Diagnosis
Allocation to intervention
Randomised controlled trial
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
Allocation is concealed using sequentially numbered, sealed opaque envelopes. Envelopes are opened only after participant eligibility has been confirmed and enrolment has occurred, preventing the treatment allocation from being known in advance.
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
A computer-generated blocked randomisation sequence was created using the Sealed Envelope Ltd online blocked randomisation list generator. Participants are allocated in a 1:1 ratio to the ultrasound-led confirmation arm or standard chest X-ray confirmation arm using randomly permuted block sizes of 4 and 6. The randomisation sequence was generated independently of the clinical team.
Masking / blinding
Open (masking not used)
Who is / are masked / blinded?



Intervention assignment
Parallel
Other design features
Phase
Not Applicable
Type of endpoint/s
Efficacy
Statistical methods / analysis
A total sample size of 132 participants (66 per group) is planned. The original study design specified a target sample size of 80 participants based on 80% statistical power. Prior to review of any unblinded outcome data, the target sample size was revised to increase statistical power and improve the precision of study estimates. A revised a priori two-tailed power calculation using an effect size of d=0.665, alpha=0.05, 95% power and 1:1 allocation indicated a requirement for 120 evaluable participants. The recruitment target was therefore increased to 132 participants (66 per group), allowing approximately 10% attrition due to withdrawals, inadequate imaging and protocol deviations. The decision to increase the sample size was based on methodological considerations and was made independently of interim treatment-effect data.

Diagnostic accuracy of point-of-care ultrasound will be assessed against the formal radiology chest X-ray report as the reference standard. Sensitivity, specificity, overall accuracy, positive and negative likelihood ratios, and agreement will be reported. Paired comparisons will use McNemar's test and paired differences in sensitivity and specificity. Time-to-confirmation outcomes are expected to be right-skewed and will be compared using the Mann-Whitney U test, with the Hodges-Lehmann estimate of the median difference and 95% confidence interval. Inter-operator reliability for ultrasound will be assessed using Cohen's kappa or intraclass correlation coefficient, as appropriate. Other outcomes will be summarised using appropriate descriptive and comparative statistics with measures of variability and 95% confidence intervals.

Recruitment
Recruitment status
Recruiting
Date of first participant enrolment
Anticipated
Actual
Date of last participant enrolment
Anticipated
Actual
Date of last data collection
Anticipated
Actual
Sample size
Target
Accrual to date
Final
Recruitment in Australia
Recruitment state(s)
SA
Recruitment hospital [1] 30142 0
Flinders Medical Centre - Bedford Park
Recruitment postcode(s) [1] 46536 0
5042 - Bedford Park

Funding & Sponsors
Funding source category [1] 322726 0
Hospital
Name [1] 322726 0
Flinders Medical Centre
Country [1] 322726 0
Australia
Primary sponsor type
Hospital
Name
Flinders Medical Centre
Address
Country
Australia
Secondary sponsor category [1] 325820 0
None
Name [1] 325820 0
Address [1] 325820 0
Country [1] 325820 0

Ethics approval
Ethics application status
Approved
Ethics committee name [1] 321169 0
Southern Adelaide Clinical Human Research Ethics Committee
Ethics committee address [1] 321169 0
Ethics committee country [1] 321169 0
Australia
Date submitted for ethics approval [1] 321169 0
29/09/2025
Approval date [1] 321169 0
15/05/2026
Ethics approval number [1] 321169 0
2025/HRE00384

Summary
Brief summary
Trial website
Trial related presentations / publications
Public notes

Contacts
Principal investigator
Name 152890 0
Prof Shailesh Bihari
Address 152890 0
Flinders Medical Centre, Intensive Care Unit, Flinders Drive, Bedford Park SA 5042
Country 152890 0
Australia
Phone 152890 0
+61 412112591
Fax 152890 0
Email 152890 0
Contact person for public queries
Name 152891 0
Nilesh Anand Devanand
Address 152891 0
Flinders Medical Centre, Intensive Care Unit, Flinders Drive, Bedford Park SA 5042
Country 152891 0
Australia
Phone 152891 0
+61 411531341
Fax 152891 0
Email 152891 0
Contact person for scientific queries
Name 152892 0
Nilesh Anand Devanand
Address 152892 0
Flinders Medical Centre, Intensive Care Unit, Flinders Drive, Bedford Park SA 5042
Country 152892 0
Australia
Phone 152892 0
+61 411531341
Fax 152892 0
Email 152892 0

Data sharing statement
Will the study consider sharing individual participant data?
No


What supporting documents are/will be available?

No Supporting Document Provided


Results publications and other study-related documents

Documents added manually
No documents have been uploaded by study researchers.

Documents added automatically