Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
A database of clinical trials and their results from Australia, New Zealand, and other countries.
account_circle
Log in
to register or update your trial
search
Search for trials
Trial Review
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12626001397303p
Ethics application status
Submitted, not yet approved
Date submitted
4/11/2026
Date registered
26/11/2026
Date last updated
26/11/2026
Date data sharing statement initially provided
26/11/2026
Type of registration
Prospectively registered
Titles & IDs
Public title
Does a wearable heart rate monitoring device improve breathing support and visual attention among healthcare professionals who are first responders during a simulated newborn resuscitation?
Query!
Scientific title
ON-BEAT: The Effect of Neobeat Heart Rate Moniroting on Mask Ventilation Performance and Visual Attention During Simulated Neonatal Resuscitation Among Healthcare Professionals who are First Responders - A Randomised Crossover Study
Query!
Additional trial identifiers [1]
318612
0
Nil
Query!
Universal Trial Number (UTN)
Query!
Trial acronym
Query!
Related trial records
Query!
Health condition
Health condition(s) studied:
Birth Asphyxia
343870
0
Query!
Condition category
Condition code
Reproductive Health and Childbirth
340014
340014
0
0
Query!
Complications of newborn
Query!
Respiratory
340265
340265
0
0
Query!
Other respiratory disorders / diseases
Query!
Intervention/exposure
Study type
Interventional
Query!
Description of the intervention or exposure
ON-BEAT is a single-site, simulation-based, two-period randomised crossover study conducted at Perth Children's Hospital. Eligible participants will be NeoResus-trained midwives, nurses and junior doctors who are not neonatal consultants or senior neonatal registrars. Each participant will complete one standardised neonatal resuscitation scenario twice in randomised order: once using NeoBeat® and once using standard care consisting of auscultation and delayed pulse oximetry, separated by a 10-minute washout period.
Three half-day simulation workshops will be conducted over one year at Perth Children's Hospital, Western Australia.
Training and familiarisation
All participants will receive training in the use of NeoBeat and have an opportunity to familiarise themselves with the device during the simulation orientation, prior to commencing the assessed scenarios.
NeoBeat device and application
NeoBeat (Laerdal Medical) is a compact, reusable, battery-powered heart rate monitor measuring approximately 83 × 87 × 40 mm and weighing 31 g. It uses dry electrodes to detect an electrocardiographic (ECG) signal and provides a continuous digital display of heart rate. The device is positioned around the newborn's torso, with electrodes contacting opposite sides of the torso. No adhesive, cables or disposable electrodes are required.
Intervention and comparison
During the intervention scenario, NeoBeat will be applied to the mannequin's chest by the midwife confederate and will display heart rate instantaneously upon application.
During the standard-care scenario, heart rate will be assessed by auscultation, with pulse oximetry available using a simulation monitor with delayed signal acquisition. After 60 seconds, heart rate and oxygen saturation values will become available. The simulation monitor will be positioned at the back right-hand corner of the resuscitaire.
Duration of intervention
Each simulation scenario will run for a maximum of two minutes from the simulated time of birth. The scenario will terminate earlier if the mannequin responds by crying, triggered by its built-in algorithm in response to adequate ventilation. The intervention and comparison conditions will therefore be assessed over a maximum of two minutes per scenario.
Query!
Intervention code [1]
335557
0
Treatment: Devices
Query!
Intervention code [2]
335707
0
Prevention
Query!
Description of the comparator or control
The comparator condition consists of standard neonatal resuscitation care, including heart rate assessment by auscultation using a stethoscope and pulse oximetry with delayed signal acquisition (60 seconds).
The mannequin's heart rate, generated by the NeoNatalie Live feedback system, will be played through a Bluetooth speaker in the room when the participant places the stethoscope on the mannequin's chest.
Heart rate and oxygen saturation values will become available on the simulation monitor after 60 seconds.
The comparator simulation will run for a maximum of two minutes from the simulated time of birth, or terminate earlier if the mannequin responds by crying, triggered by its built-in algorithm in response to adequate ventilation.
The comparator condition will be assessed as part of the study, with ventilation performance and visual attention measured using the same methods as in the intervention condition.
Query!
Control group
Active
Query!
Outcomes
Primary outcome [1]
347339
0
Mask leak
Query!
Assessment method [1]
347339
0
Mask leak will be measured using the Pnemotach RFM (GE Healthcare neonatal flow sensor by Accutronic Medical Systems). This device will be placed in the NeoPuff circuit between the mask and the T-piece. The device records breath-by-breath inspiratory and expiratory tidal volumes, allowing calculation of mask leak as ((VTi - VTe) / VTi) × 100, peak inspiratory and expiratory pressure, mean airway pressure and ventilation rate. Data captured by the Pneumotach RFM will not be displayed at the time of the simulations but will be downloaded afterwards for outcome measurement analysis.
Query!
Timepoint [1]
347339
0
During the first 60 seconds of mask veniltation in both the Neobeat intervention and standard-care comparator simulations.
Query!
Secondary outcome [1]
470321
0
Visual attention. Proportion of total simulation time spent fixating on predefined areas of interest (AOIs): airway/chest, oximeter and confederate midwife.
Query!
Assessment method [1]
470321
0
Tobii 3.0 research grade eye tracking glasses
Query!
Timepoint [1]
470321
0
During the first 60 seconds of mask veniltation in both the Neobeat intervention and standard-care comparator simulations.
Query!
Secondary outcome [2]
470322
0
NASA- Task Load Index (NASA-TLX)
Query!
Assessment method [2]
470322
0
Perceived workload will be assessed using the validated raw NASA Task Load Index (NASA-TLX). The primary workload measure will be the overall score (0–100), calculated as the unweighted mean of six domains: mental demand, physical demand, temporal demand, performance, effort and frustration. Individual domain scores will be examined descriptively as exploratory measures and will not be combined into a separate composite outcome.
Query!
Timepoint [2]
470322
0
At the end of both Neobeat intervention and standard-care simulation
Query!
Secondary outcome [3]
470323
0
Time to first breath
Query!
Assessment method [3]
470323
0
Stop watch from time of birth to first breath delivered, observed by research assistant.
Query!
Timepoint [3]
470323
0
Assessed during both the Neobeat intervention and standard-care comparator simulations, from simulated birth until the first positive-pressure ventilation is delivered (maximum two minutes).
Query!
Secondary outcome [4]
470324
0
Chest compressions intiated (yes or no)
Query!
Assessment method [4]
470324
0
Whether chest compressions were initiated (yes/no), and time to initiation if performed. Recorded on data sheet.
Query!
Timepoint [4]
470324
0
During the first 60 seconds of mask veniltation in both the Neobeat intervention and standard-care comparator simulations.
Query!
Secondary outcome [5]
470325
0
Participant assessment of chest rise
Query!
Assessment method [5]
470325
0
Likert scale; 0 chest rise very difficult and 4 very easy to assess.
Query!
Timepoint [5]
470325
0
At the end of both Neobeat intervention and standard-care simulation
Query!
Secondary outcome [6]
470326
0
Ventilation rate
Query!
Assessment method [6]
470326
0
Pnemotach RFM (GE Healthcare neonatal flow sensor by Accutronic Medical Systems).
Query!
Timepoint [6]
470326
0
During the first 60 seconds of mask veniltation in both the Neobeat intervention and standard-care comparator simulations.
Query!
Secondary outcome [7]
470327
0
Peak Inspiratory Pressure
Query!
Assessment method [7]
470327
0
Pnemotach RFM (GE Healthcare neonatal flow sensor by Accutronic Medical Systems).
Query!
Timepoint [7]
470327
0
During the first 60 seconds of mask veniltation in both the Neobeat intervention and standard-care comparator simulations.
Query!
Secondary outcome [8]
470782
0
Gaze Patterns Number and sequence of gaze transitions between predefined areas of interest, Gaze patterns will be analyzed to characterize how participants distrubite and shift their visual attention during neonatal resuscitation.
Query!
Assessment method [8]
470782
0
Tobii 3.0 research grade eye tracking glassess
Query!
Timepoint [8]
470782
0
During the first 60 seconds of mask veniltation in both the Neobeat intervention and standard-care comparator simulations.
Query!
Secondary outcome [9]
470783
0
Mean pupil diameter (mm), as an exploratory indicator of physiological response.
Query!
Assessment method [9]
470783
0
Tobii 3.0 research grade eye tracking glasses
Query!
Timepoint [9]
470783
0
During the first 60 seconds of mask veniltation in both the Neobeat intervention and standard-care comparator simulations.
Query!
Eligibility
Key inclusion criteria
Nurses, Midwives and Doctors working within Western Australia. Participants must have completed the statewide neonatal resuscitation program NeoResus.
Query!
Minimum age
25
Years
Query!
Query!
Maximum age
65
Years
Query!
Query!
Sex
Both males and females
Query!
Healthy volunteers
Yes
Query!
Key exclusion criteria
Senior registrars and consultant neonatologists (classified as specialists) will be excluded.
Query!
Study design
Purpose of the study
Treatment
Query!
Allocation to intervention
Randomised controlled trial
Query!
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
Allocation concealment will be maintained using the REDCap® Randomisation module. The underlying randomisation schedule will not be accessible to personnel enrolling participants. Following informed consent and enrolment, the participant’s study ID and clinical-role stratum will be entered into REDCap®, which will reveal only the participant’s assigned intervention sequence.
Personnel enrolling participants will not have access to future allocations in the randomisation schedule.
Query!
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
The randomisation schedule will be generated and configured in REDCap® before recruitment begins. Following enrolment, an authorised study team member will enter the participant’s study ID and clinical-role stratum into the REDCap® Randomisation module to obtain the allocated intervention sequence.
Query!
Masking / blinding
Open (masking not used)
Query!
Who is / are masked / blinded?
Query!
Query!
Query!
Query!
Intervention assignment
Crossover
Query!
Other design features
Query!
Phase
Not Applicable
Query!
Type of endpoint/s
Efficacy
Query!
Statistical methods / analysis
The study will use a two-period crossover design, with participants randomised to either standard care followed by NeoBeat® or NeoBeat® followed by standard care. The primary outcome will be participant-level mean mask leak (%) during the first 60 seconds of ventilation, calculated separately for each participant under each condition after prespecified data-cleaning procedures have been applied. Individual breaths will not be treated as independent observations.
The primary analysis will compare mask leak between NeoBeat® and standard care using a participant-level crossover analysis that accounts for the paired nature of the data. Period and intervention sequence will be considered in the analysis to assess potential learning or period effects. Results will be reported as the estimated treatment effect with 95% confidence intervals and a two-sided p-value, with statistical significance defined as p<0.05.
Secondary ventilation outcomes, including ventilation rate and peak inspiratory pressure, will be analysed using paired or mixed-effects methods as appropriate to the distribution and structure of the data. Visual-attention outcomes and NASA-TLX scores will be compared between conditions using participant-level paired analyses or regression models as appropriate. Time-to-event outcomes, including time to first effective ventilation, will be analysed using an appropriate paired time-to-event method if event frequencies permit. Chest-compression outcomes will be summarised descriptively and analysed comparatively where sufficient events occur.
The primary analysis population will include all randomised participants who provide evaluable outcome data under both study conditions. Participants with incomplete paired primary-outcome data will not contribute to the primary paired analysis but will be included in relevant secondary or descriptive analyses where valid data are available. The extent and reasons for missing data will be reported. No routine imputation of missing primary-outcome data is planned; if missing data are greater than anticipated, sensitivity analyses will be considered.
For ON-BEAT, a formal Data Monitoring Committee (DMC) is not really warranted because this is a low-risk, short-duration simulation study with no patient treatment and no clinical intervention.
Query!
Recruitment
Recruitment status
Not yet recruiting
Query!
Date of first participant enrolment
Anticipated
7/12/2026
Query!
Actual
Query!
Date of last participant enrolment
Anticipated
17/12/2027
Query!
Actual
Query!
Date of last data collection
Anticipated
17/12/2027
Query!
Actual
Query!
Sample size
Target
50
Query!
Accrual to date
Query!
Final
Query!
Recruitment in Australia
Recruitment state(s)
WA
Query!
Funding & Sponsors
Funding source category [1]
323187
0
Charities/Societies/Foundations
Query!
Name [1]
323187
0
Women's and Infants Research Foundation
Query!
Address [1]
323187
0
Query!
Country [1]
323187
0
Australia
Query!
Primary sponsor type
Individual
Query!
Name
Alexander Wilson - Perth Children's Hospital
Query!
Address
Query!
Country
Australia
Query!
Secondary sponsor category [1]
326155
0
Government body
Query!
Name [1]
326155
0
Child and Adolescent Health Service (CAHS)
Query!
Address [1]
326155
0
Query!
Country [1]
326155
0
Australia
Query!
Ethics approval
Ethics application status
Submitted, not yet approved
Query!
Ethics committee name [1]
321592
0
WA Health Central HREC
Query!
Ethics committee address [1]
321592
0
https://www.health.wa.gov.au/Articles/U_Z/WA-Health-Central-HREC
Query!
Ethics committee country [1]
321592
0
Australia
Query!
Date submitted for ethics approval [1]
321592
0
06/11/2026
Query!
Approval date [1]
321592
0
Query!
Ethics approval number [1]
321592
0
Query!
Summary
Brief summary
Effective breathing support is essential for newborn babies who need resuscitation immediately after birth. Healthcare professionals use a baby's heart rate to assess how well this support is working, but traditional methods may delay this information. This study will investigate whether NeoBeat, a device that provides continuous, real-time heart rate monitoring, improves the quality of breathing support and changes where healthcare professionals focus their attention during resuscitation. Midwives, nurses and junior doctors will each complete two simulated newborn resuscitations in random order: one using NeoBeat and one using standard heart rate assessment. Researchers will compare the amount of air leaking around the face mask, the effectiveness of ventilation and where participants direct their visual attention, to determine whether faster heart rate feedback improves resuscitation performance.
Query!
Trial website
Query!
Trial related presentations / publications
Query!
Public notes
Query!
Contacts
Principal investigator
Name
154186
0
Dr Alexander Wilson
Query!
Address
154186
0
Perth Children's Hospital, 15 Hospital Ave, Nedlands, Western Australia, 6009
Query!
Country
154186
0
Australia
Query!
Phone
154186
0
+61413445793
Query!
Fax
154186
0
Query!
Email
154186
0
[email protected]
Query!
Contact person for public queries
Name
154187
0
Alexander Wilson
Query!
Address
154187
0
Perth Children's Hospital, 15 Hospital Ave, Nedlands, Western Australia, 6009
Query!
Country
154187
0
Australia
Query!
Phone
154187
0
+61413445793
Query!
Fax
154187
0
Query!
Email
154187
0
[email protected]
Query!
Contact person for scientific queries
Name
154188
0
Alexander Wilson
Query!
Address
154188
0
Perth Children's Hospital, 15 Hospital Ave, Nedlands, Western Australia, 6009
Query!
Country
154188
0
Australia
Query!
Phone
154188
0
+61413445793
Query!
Fax
154188
0
Query!
Email
154188
0
[email protected]
Query!
Data sharing statement
Will the study consider sharing individual participant data?
Yes
Will there be any conditions when requesting access to individual participant data?
Persons/groups eligible to request access:
•
Researchers
Conditions for requesting access:
•
Yes, conditions apply:
•
Requires review on a case-by-case basis by the trial custodian, sponsor or data sharing committee
What individual participant data might be shared?
•
All de-identified individual participant data
What types of analyses could be done with individual participant data?
•
Any type of analysis (i.e. no restrictions on data re-use)
When can requests for individual participant data be made (start and end dates)?
From:
After publication of main results
To:
Not yet decided
Where can requests to access individual participant data be made, or data be obtained directly?
•
Email of trial custodian, sponsor or committee:
[email protected]
Are there extra considerations when requesting access to individual participant data?
No
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
No additional documents have been identified.
Download to PDF